GF333B three phase reference standard meter is a high accuracy portable reference standard energy meter used to test three phase meters and single phase meters error, it designed to work both in the field and in the laboratory. The GF333B reference meter is used to measure three phase AC energy and voltage, current, power, phase angle, harmonic and other parameters in lab, and it also can be used to integrated in the energy meter test system and supply the standard energy pulse and every measurement parameters. Its stability 0.005%/min.
Electrical parameters | |
---|---|
Accuracy | 0.04%, 0.05% |
Voltage supply | 220V±10% or 110V±10%, 50/60Hz |
Power consumption | 15VA |
Warming-up time | <30min |
Voltage measurement(U1 U2 U3 UN) | |
Range | 0V-600V |
Error | ±0.02% (50V-600V), ±0.05% (5V-40V) |
Display range | 0.000000V-600.0000V |
Harmonic | 2nd-128st |
Current measurement(I1 I2 I3) | |
Range | 1mA-120A |
Error | ±0.02% (0.1A-120A), ±0.05% (1mA-0.1A) |
Display range | 1.000000mA-120.0000A |
Harmonic | 2nd-128st |
Power measurement | |
Active power | ±0.02% (0.1A-120A) ±0.05% (0.01A-0.1A) ±0.1% (0.001A-0.01A) |
Reactive power | ±0.05% (0.1A-120A), ±0.1% (0.001A-0.1A) |
Apparent power | ±0.05% (0.1A-120A), ±0.1% (0.001A-0.1A) |
Energy error | |
Active energy | ±0.02% (0.1A-120A) ±0.05% (0.01A-0.1A) ±0.1% (0.001A-0.01A) |
Reactive energy | ±0.05% (0.1A-120A), ±0.1% (0.001A-0.1A) |
Apparent energy | ±0.05% (0.1A-120A), ±0.1% (0.001A-0.1A) |
Phase measurement | |
Range | 0°-360° |
Error | ±0.01° |
Display range | 0.0000°-359.999° |
Frequency measurement | |
Range | 40-70Hz |
Display range | 40.0000-70.0000 |
Resolution | 0.0005 |
Accuracy | 0.001Hz |
Power Factor measurement | |
Range | -1.00000 ~ 0 ~ +1.00000 |
Resolution | 0.0001 |
Accuracy | 0.0005 |
Energy pulse | |
High frequency output(CH) | 12000Hz |
Low frequency output(CL) | 5000Hz |
Pulse ratio | 1:1 |
Output level | 5V |
Input level | 5V |
Input frequency | Max. 1MHz |
Function | |
LCD Display | 6 inch color touch display |
Vector diagram | Yes |
Waveform | Yes |
Energy accumulation | Yes |
Harmonic | Yes |
Self-calibration | Yes |
Data storage | Yes |
PC software | Optional |
Communication port | RS232 |
Standard | |
Standard | IEC 62053-21,22, 23; IEC 60736; IR46; ANSI C12.20-2022; JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019; DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016 |
Safety | |
Isolation protection | IEC 61010-1:2001 |
Measurement Category | 300 V CAT III, 600 V CAT II |
Degree of protection | IP40 |
Declaration of conformity | CE & CNAS certified |
Mechanical parameters | |
Dimensions (W×H×D) (mm) | 480×138×486 |
Weight (kg) | 8.5 |
Environmental conditions | |
Ambient temperature | -10°C to 45°C |
Storage temperature | -20°C to 65°C |
Relative humidity | 10%-85% |
Influence of external fields | ≤0.05 %/mT |
Temperature coefficient | ≤0.0005% /℃ |