The GF101 single phase phantom load power source for testing energy meter is equipped with RS232 port as standard communication interface to control external devices remotely. In the power calibration mode, the GF101 programmable phantom load power source can be used as a source to calibrate single-phase AC watt meters, power analyzers, and energy meters. In this mode, the output voltage can be set up from 0 to 600V, the output current from 0 to 120A, and the power factor from -1.00000 to +1.00000 lead/lag in the frequency band from 40Hz to 70Hz. Power factor is an important element when users judge the efficiency of a device. It is suitable for power department, metrological department, quality control department, research units, institution of higher learning, electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as high accuracy 0.02% single phase voltage source, current source and power source.
| Electrical parameters | |
|---|---|
| Accuracy class | 0.02%, 0.05%, 0.1% |
| Power supply | Single phase AC 85-265V, 50/60Hz |
| AC Voltage output | |
| Range | 57.7V/100V/220V/380V, switch automatically (max 500V or 600V) |
| Adjustment resolution | 0.01%, 0.1%, 1%, 10% |
| Accuracy | 0.02%RG, 0.05%RG |
| Stability | Better than 0.01%RG/1min |
| Distortion degree | Better than 0.1% (not capacitive load) |
| Load capacity | 25VA or 50VA |
| Full load regulation rate | Less than 0.01%RG |
| Full load regulation time | Less than 1ms |
| Temperature drift | 8PPM/°C |
| Long-term stability | 60PPM/year |
| AC current output | |
| Range | 0.1A/0.25A/0.5A/1A/5A/10A/20A/50A/100A/200A, Switch automatically (max 120A or 240A) |
| Adjustment resolution | 0.01%, 0.1%, 1%, 10% |
| Accuracy | 0.02%RG, 0.05%RG |
| Stability | Better than 0.01%RG/1min |
| Distortion degree | Better than 0.1% (not capacitive load) |
| Load capacity | 50VA, 100VA, 200VA, 500VA |
| Full load regulation rate | Less than 0.01%RG |
| Full load regulation time | Less than 1mS |
| Temperature drift | 8PPM/°C |
| Long-term stability | 60PPM/year |
| Power output | |
| Active power accuracy | 0.02%, 0.05%, 0.1% |
| Reactive power accuracy | 0.1% |
| Stability | Better than 0.01% RG/1min |
| Phase angle | |
| Range | 0.000°-359.999° |
| Output adjustment fineness | 10°, 1°, 0.1°, 0.01° as optional. |
| Resolution | 0.001° |
| Accuracy | 0.02°, 0.05° |
| Power factor | |
| Adjusting range | -1~0~+1 |
| Resolution | 0.0001 |
| Accuracy | 0.0005 |
| Frequency | |
| Range | 40.000-70.000Hz |
| Output adjustment fineness | 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. |
| Resolution | 0.001Hz |
| Accuracy | 0.002Hz |
| Temperature drift | 0.5PPM/°C |
| Long-term stability | 4PPM/year |
| Harmonic | |
| Harmonic times | 2nd-63th |
| Adjustment resolution | 0.1% (compared with fundamental wave) |
| Harmonic content (compared with fundamental wave) | |
| Voltage | ≤40% |
| Current | ≤40% |
| Phase | 0°-360.00° |
| Functions | |
| Communication port | RS232 |
| Programmable controlled | Yes |
| Harmonics | Yes |
| Key | 20pcs |
| LCD | 6 inch TFT color touch display |
| PC control software | Optional |
| Standard | |
| Standard | IEC 62053-21,22,23; IEC 60736; ANSI C12.20-2002; JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019; DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016; JJG 51-1999; DL/T 2213.1-2021; GJB J 5857-2006; JJG6-2011; JJG70-2015; |
| Safety | |
| Isolation protection | IEC 61010-1: 2001 |
| Measurement category | 300V CAT III, 600V CAT II |
| Degree of protection | IP20 |
| Declaration of conformity | CE & CNAS certified |
| Mechanical parameters | |
| Dimensions (W×D×H)(mm) | 420×320×155 |
| Weight (kg) | 12 |
| Environmental conditions | |
| Operating temperature | 0°C to 50°C |
| Storage conditions | -30°C to 60°C |
| Relative humidity | ≤85% |
| No. | Accuracy | Voltage range | Current range | Weight |
|---|---|---|---|---|
| 1011201 | 0.1% | 0-500V | 0-120A | 12KG |
| 10112005 | 0.05% | 0-500V | 0-120A | 12KG |
| 101201 | 0.1% | 0-500V | 0-120A | 10KG |
| 1012005 | 0.05% | 0-500V | 0-120A | 10KG |
| 101121 | 0.1% | 0-500V | 0-12A | 8KG |
| 1011205 | 0.05% | 0-500V | 0-12A | 8KG |
| 101T1201 | 0.1% | 0-1000V | 0-120A | 13KG |
| 101T12005 | 0.05% | 0-1000V | 0-120A | 13KG |
| 101D2001 | 0.1% | 0-600V | 0-200A | 20KG |
| 101D20005 | 0.05% | 0-600V | 0-200A | 20KG |